TM-9-2320-366-20-1 MTV Unit Maintenance Manual M1083 Series - Volume 1 Download

Page 449 of 1824

CONTINUITY TEST (1) Remove circuit breaker CB36 from PDP. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to relay K2 socket 87 on PDP. (4) Connect negative (-) probe of multimeter to circuit breaker CB36 socket 6 on PDP and note reading on multimeter. (5) If continuity is not present, repair wire 1604 from relay K2 socket 87 on PDP to bus bar X6 on PDP (para 2-45) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (6) If continuity is present, replace bus bar X6 on PDP or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (7) Install circuit breaker CB36 in PDP. (8) Install relay K2 in PDP. (9) Install power distribution panel (PDP) cover (para 16-2). (10) Connect batteries (para 7-57). TM 9-2320-366-20-1 Change 1 2-284.1