TM-9-2320-366-20-1 MTV Unit Maintenance Manual M1083 Series - Volume 1 Download

Page 410 of 1824

e3. 12 VDC AND 24 VDC CIRCUITS DO NOT OPERATE (CONT) KNOWN INFO TEST OPTIONS NO YES Is continuity present from starting motor ground terminal stud to terminal lug TL45? Replace starter to shunt 24 VDC cable (para 7-134). Circuit breaker CB70 OK. Battery(ies) OK. Cab to chassis ground strap OK. PDP to cab ground cable OK. Shunt OK. POSSIBLE PROBLEMS Faulty starter to shunt 24 VDC cable. Faulty battery to shunt cable assembly. Faulty starter to chassis ground cable. 9. REASON FOR QUESTION If continuity is not present, starter to shunt 24 VDC cable is faulty. Continuity Test or STE/ICE-R Test #91 TM 9-2320-366-20-1 2-266.14 Change 1