TM-9-2320-366-20-1 MTV Unit Maintenance Manual M1083 Series - Volume 1 Download
Page 405 of 1824
CONTINUITY TEST (1) Remove self-locking nut, washer, terminal lug TL65, and lockwasher from stud. Discard self-locking nut and lockwasher. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to terminal lug TL65. (4) Connect negative (-) probe of multimeter to terminal lug TL64 and note reading on multimeter. (5) If continuity is not present, replace cab to chassis ground strap (para 7-78). (6) Install lockwasher and terminal lug TL65 on stud with washer and self-locking nut. Install plastic cable ties as required. (7) Position front grille on cab with washer and screw. (8) Position two washers and screws in front grille. (9) Tighten screw to 48-60 lb-in. (5-7 N.m). (10) Tighten two screws to 24 lb-in. (3 N.m). NOTE TM 9-2320-366-20-1 Change 1 2-266.9