TM-9-2320-366-20-1 MTV Unit Maintenance Manual M1083 Series - Volume 1 Download

Page 369 of 1824

CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to relay K26 socket 85 on PDP. (3) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (4) If continuity is not present, repair wire 3102 from relay K26 socket 85 on PDP to terminal board TB2 position 17 (para 2-45) or replace WTEC III dashboard cable assembly (para 7-11). TM 9-2320-366-20-1 Change 1 2-239