RESISTANCE TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to relay K1 terminal 86. (3) Connect negative (-) probe of multimeter to relay K1 terminal 85 and note reading on multimeter. (4) If 306-399 ohms resistance is not present, replace relay K1 (para 7-9). (5) If 306-399 ohms resistance is present, repair wire 74 from relay K1 socket 30 on PDP to relay K24 socket 30 on PDP (para 2-45) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (6) Disconnect batteries (para 7-57). (7) Install relay K1 in PDP. (8) Install PDP cover (para 16-2). (9) Connect batteries (para 7-57). TM 9-2320-366-20-1 Change 1 2-207