TM-9-2320-366-20-1 MTV Unit Maintenance Manual M1083 Series - Volume 1 Download

Page 325 of 1824

VOLTAGE TEST WARNING Remove rings, bracelets, watches, necklaces, and any other jewelry before working around vehicle. Jewelry can catch on equipment and cause injury or short across electrical circuits and cause severe burns or electrical shock. (1) Disconnect batteries (para 7-57). (2) Remove relay K1 from PDP. (3) Connect batteries (para 7-57). (4) Set multimeter to volts DC. (5) Connect positive (+) probe of multimeter to PDP relay K1 socket 30. (6) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (7) If 24 VDC is not present, repair wire 1602 from relay K1 socket 30 on PDP to unmarked terminal lug (para 2-45) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). TM 9-2320-366-20-1 Change 1 2-195