(1) Remove nut, lockwasher, and terminal lug TL24 from auxiliary starter solenoid. Discard lockwasher. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to terminal lug TL24. (4) Connect negative (-) probe of multimeter to terminal lug TL26 and note reading on multimeter. (5) If continuity is not present, repair wire 14A from terminal lug TL24 to terminal lug TL26 (para 2-45) or replace start and charging cable assembly (para 7-132). (6) If continuity is present, replace auxiliary starter solenoid (para 7-6). (7) Install terminal lug TL24 on auxiliary starter solenoid with lockwasher and nut. (8) Apply adhesive to auxiliary starter solenoid. (9) Apply adhesive to solenoid right terminal stud. (10) Lower cab (TM 9-2320-366-10-1). (11) Connect batteries (para 7-57). CONTINUITY TEST TM 9-2320-366-20-1 Change 1 2-177