TM-9-2320-366-20-1 MTV Unit Maintenance Manual M1083 Series - Volume 1 Download

Page 305 of 1824

CONTINUITY TEST (1) Disconnect batteries (para 7-57). (2) Remove nut, lockwasher, and terminal lug TL23 from auxiliary starter solenoid. Discard lockwasher. (3) Set multimeter to ohms. (4) Connect positive (+) probe of multimeter to terminal lug TL23. (5) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (6) If continuity is not present, repair wire 93 from terminal lug TL23 to terminal lug TL25 (para 2-45) or replace start and charging cable assembly (para 7-132). (7) Install terminal lug TL23 on auxiliary starter solenoid with lockwasher and nut. TM 9-2320-366-20-1 Change 1 2-175