TM 9-2320-366-20-1 Table 2-1. Preventive Maintenance Checks and Services (Cont) Item No. Interval Location Item to be Checked or Serviced Procedure Not Fully Mission Capable If: 52 Semiannual 15K SRW CABLE WARNING Cable can become frayed or contain broken wires. Wear heavy leather gloves when handling cable. Frayed or broken wires can injure hands. Failure to comply may result in injury to personnel. a. Spool out 15K SRW cable completely (TM 9-2320-366-20-2); and inspect for kinks, sharp bends, abrasions, and broken wires. b. Check that there are no more than six randomly distributed broken wires in any six- inch section of cable or three broken wires in one bundle (breaks 3, 4, 5) in a six-inch section. result b. More than six broken wires in a six-inch section or three broken wires in one bundle in a six- inch section is evident. c. Kinking, crushing, or any other damage resulting in distortion of the cable structure. 2-54