TM-9-2320-366-20-1 MTV Unit Maintenance Manual M1083 Series - Volume 1 Download

Page 1505 of 1824

TM 9-2320-366-20-1 TM 9-2320-366-20-1 TM 9-2320-366-20-1 TM 9-2320-366-20-1 TM 9-2320-366-20-1 CONTINUITY TEST CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector PX7-17. (3) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (4) If continuity is not present, repair wire 3030 (para 2-45) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector PX7-2. (3) Connect negative (-) probe of multimeter to connector PX7-17 and note reading on multimeter. (4) If continuity is not present, replace lighted indicator display (para 7-16). (5) If continuity is present, replace chemical detector (notify NBC). (6) Connect lighted indicator display to connector PX7. (7) Position lighted indicator display in instrument panel assembly with four screws. (8) Tighten four screws to 6-10 lb-in. (1 N·m). (9) Connect batteries (para 7-57). 2-941/(2-942 Blank) 2-941/(2-942 Blank) 2-941/(2-942 Blank) 2-941/(2-942 Blank) 2-941/(2-942 Blank)