TM-9-2320-366-20-1 MTV Unit Maintenance Manual M1083 Series - Volume 1 Download

Page 1492 of 1824

TM 9-2320-366-20-1 TM 9-2320-366-20-1 TM 9-2320-366-20-1 TM 9-2320-366-20-1 TM 9-2320-366-20-1 2-928 2-928 2-928 2-928 2-928 1. START YES NO Chemical detector indicator operates. If 12 vdc is not present, wire 1803 is faulty. KNOWN INFO POSSIBLE PROBLEMS WARNING Read WARNING on following page. TEST OPTIONS Voltage Test or STE/ICE-R #89 REASON FOR QUESTION Is 12 vdc present at terminal lug TL97? Go to step 3 of this fault. INITIAL SETUP Equipment Condition Engine shut down (TM 9-2320-366-10-1). Personnel Required (2) Tools and Special Tools Tool Kit, Genl Mech (Item 46, Appendix C) STE/ICE-R (Item 41, Appendix C) Multimeter, Digital (Item 22, Appendix C) References TM 9-4910-571-12&P Faulty dashboard cable assembly. Faulty chemical alarm kit cable assembly. Faulty chemical alarm. e83. CHEMICAL ALARM DOES NOT OPERATE