TM-9-2320-366-20-1 MTV Unit Maintenance Manual M1083 Series - Volume 1 Download

Page 1426 of 1824

TM 9-2320-366-20-1 TM 9-2320-366-20-1 TM 9-2320-366-20-1 TM 9-2320-366-20-1 TM 9-2320-366-20-1 2-862 2-862 2-862 2-862 2-862 YES NO START 1. Circuit breaker OK. Main instrument panel illuminates. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS Continuity Test or STE/ICE-R #91 REASON FOR QUESTION INITIAL SETUP Equipment Condition Engine shut down (TM 9-2320-366-10-1). Personnel Required (2) References TM 9-4910-571-12&P Tools and Special Tools Tool Kit, Genl Mech (Item 46, Appendix C) STE/ICE-R (Item 41, Appendix C) Multimeter, Digital (Item 22, Appendix C) Faulty lamps. Faulty dashboard cable assembly. Faulty personnel heater. Is continuity present through lamps? If continuity is not present, lamps are faulty. e75. PERSONNEL HEATER CONTROL ILLUMINATION DOES NOT OPERATE Replace lamps (para 18-9).