TM-9-2320-366-20-1 MTV Unit Maintenance Manual M1083 Series - Volume 1 Download

Page 1337 of 1824

TM 9-2320-366-20-1 TM 9-2320-366-20-1 TM 9-2320-366-20-1 TM 9-2320-366-20-1 TM 9-2320-366-20-1 2-773 2-773 2-773 2-773 2-773 VOLTAGE TEST Remove rings, bracelets, watches, necklaces, and any other jewelry before working around vehicle. Jewelry can catch on equipment and cause injury or short across electrical circuit and cause severe burns or electrical shock. WARNING (1) Remove PDP cover (para 16-2). (2) Remove relay K6 from PDP. (3) Set multimeter to volts dc. (4) Connect positive (+) probe of multimeter to PDP, terminal 86, where relay K6 was removed. (5) Connect negative (-) probe of multimeter to ground. (6) Position master power switch to on (TM 9-2320-366-10-1) and note reading on multimeter. (7) If 12 vdc is not present, go to step 7 of this fault. (8) Position master power switch to off (TM 9-2320-366-10-1).