TM 9-2320-366-20-1 Change 1 2-748.1 CONTINUITY TEST (1) Remove instrument panel assembly for access (para 7-15). (2) Disconnect turn signal switch connector from connector J19. (3) Position turn signal switch to center position (TM 9-2320-366-10-1). (4) Set multimeter to ohms. (5) Connect positive (+) probe of multimeter to turn signal switch connector socket 6. (6) Connect negative (-) probe of multimeter to turn signal switch connector socket 2 (LH) or socket 3 (RH) and note reading on multimeter. (7) If continuity is not present, replace turn signal switch (para 7-26). (8) Connect connector J19 to turn signal switch connector. (9) Install instrument panel assembly (para 7-15). Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back and are capable of making good contact. NOTE Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment. CAUTION