Change 1 2-705/(2-706 Blank) TM 9-2320-366-20-1 All data on pages 2-706 and 2-707 deleted. (1) Install new WTEC III relay K25 on PDP. (2) Start engine (TM 9-2320-366-10-1). (3) Position main light switch to SER DRIVE (TM 9-2320-366-10-1). (4) Select R (reverse) on WTEC III TPSS (TM 9-2320-366-10-1). (5) Check to see if backup lights operate. (6) Select N (neutral) on WTEC III TPSS (TM 9-2320-366-10-1). (7) Position main light switch to OFF (TM 9-2320-366-10-1). (8) Shut down engine (TM 9-2320-366-10-1). (9) Remove new WTEC III relay K25 from PDP. (10) Install old WTEC III relay K25 on PDP. (11) If backup lights operate, replace WTEC III relay K25 (para 7-9). (12) If backup lights do not operate, replace WTEC III transmission ECU (para 8-7). (13) Install kick panel (para 16-3).