CONTINUITY TEST  Change 1 2-687  TM 9-2320-366-20-1  (1) Remove three screws from PDP.  (2) Remove three screws and washers from  PDP.  (3) Lift PDP outward to gain access.  (4) Disconnect connector P51 from connector  J51.  (5) Set multimeter to ohms.  (6) Connect positive (+) probe of multimeter  to connector PX33 socket A1.  (7) Connect negative (-) probe of multimeter to  connector J51 pin 2 and note reading on  multimeter.  (8) If continuity is not present, repair wire 490  from connector PX33 socket A1 to  connector J51 pin 2 (para 2-45) or replace  WTEC II dashboard cable assembly  (para 7-10).  (9) Connect connector PX33 to WTEC II VIM.  (10) Tighten screw in connector PX33.  (11) Install kick panel (para 16-3).  Inspect connector pins/sockets for damage,  corrosion, and serviceability. Check that  connector pins are not pushed back and  are capable of making good contact.  NOTE  Use care when testing electrical connectors.  Do not damage connector pins or sockets  with multimeter probes. Failure to comply  may result in damage to equipment.  CAUTION