Change 1 2-671 TM 9-2320-366-20-1 CONTINUITY TEST (1) Remove lens from housing. (2) Remove preformed packing from housing. Discard preformed packing. (3) Remove two lamps from sockets. (4) Set multimeter to ohms. (5) Connect positive (+) probe of multimeter to center contact of lamp. (6) Connect negative (-) probe of multimeter to lamp base and note reading on multimeter. (7) If continuity is not present, replace one or both lamps (para 7-36). (8) Install two lamps in sockets. (9) Install preformed packing and lens on housing with six captive screws. (10) Connect batteries (para 7-57).