TM-9-2320-366-20-1 MTV Unit Maintenance Manual M1083 Series - Volume 1 Download
Page 1143 of 1824
TM 9-2320-366-20-1 CONTINUITY TEST CAUTION Change 1 2-612.17 (1) Disconnect connector P52R from connector J52. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to connector P52R socket 4. (4) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (5) If continuity is not present, repair wire 3094 from terminal lug TL92 to splice E59 (para 2-45) or replace M1089 rear lights cable assembly (para 7-104). (6) If continuity is present, repair wire 3094 from splice E59 to terminal lug TL21 (para 2-45) or replace rear lights cable assembly (para 7-104). (7) Connect connector J52 to connector P52R. Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back and are capable of making good contact. NOTE Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment.