TM-9-2320-366-20-1 MTV Unit Maintenance Manual M1083 Series - Volume 1 Download

Page 1139 of 1824

TM 9-2320-366-20-1 Change 1 2-612.13 (1) Remove two screws, lockwashers, LH composite taillight assembly, and terminal lug TL18 from right taillight carrier. Discard lockwashers. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to terminal lug TL18. (4) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (5) If continuity is not present, go to step 21 of this fault. (6) If continuity is present, replace LH composite taillight assembly (para 7-39). (7) Install terminal lug TL18, and LH composite taillight assembly on left taillight carrier with two lockwashers and screws. (8) Connect connector P78 to LH composite taillight assembly. (9) Install LH composite taillight lamp in socket. (10) Install preformed packing and cover on LH composite taillight assembly with six screws. CONTINUITY TEST