TM 9-2320-366-20-1 Change 1 2-604.95 CONTINUITY TEST (1) Remove two screws and lens cover from LH intermediate marker light base. (2) Remove LH intermediate marker light lamp from socket. (3) Set multimeter to ohms. (4) Check continuity through LH intermediate marker light lamp and note reading on multimeter. (5) If continuity is not present, replace LH intermediate marker light lamp (para 7-38) and go to step 5 of this fault if required. (6) Install LH intermediate marker light lamp in socket. (7) Install lens cover on LH intermediate marker light base with two screws.