TM 9-2320-366-10-2 Table 3-2. Troubleshooting (Cont) MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION e143. TRANSMISSION AUXILIARY OIL COOLER FAN DOES NOT OPERATE (ALL MODELS EXCEPT M1088/M1089). Check circuit breaker (CB68) in PDP to see if it is tripped. (a) Remove PDP cover (para 3-17a). (b) Position master power switch to off (para 2-27f). (c) If circuit breaker is tripped, push in to reset. (d) Position master power switch to on (para 2-27a or b). (e) Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance. (f) Position master power switch to off (para 2-27f). (g) Install PDP cover (para 3-17b). (h) If transmission auxiliary oil cooler fan still does not operate, notify Unit Maintenance. e144. M1088/M1089 TRANSMISSION AUXILIARY OIL COOLER FAN DOES NOT OPERATE. Check circuit breaker (CB68) in PDP to see if it is tripped. (a) Remove PDP cover (para 3-17a). (b) Position master power switch to off (para 2-27f). (c) If circuit breaker is tripped, push in to reset. (d) Position master power switch to on (para 2-27a or b). (e) Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance. (f) Position master power switch to off (para 2-27f). (g) Install PDP cover (para 3-17b). (h) If transmission auxiliary oil cooler fan still does not operate, notify Unit Maintenance. e145. M1088/M1089 WORKLIGHTS DO NOT ILLUMINATE. Check circuit breaker (CB72) in PDP to see if it is tripped. (a) Remove PDP cover (para 3-17a). (b) Position master power switch to off (para 2-27f). (c) If circuit breaker is tripped, push in to reset. (d) Position master power switch to on (para 2-27a or b). Change 1 3-79