TM-9-2320-366-10-2 MTV Operator Manual M1083 Series - Volume 2 Download

Page 537 of 930

TM 9-2320-366-10-2 Table 3-2. Troubleshooting (Cont) MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION e16a. ETHER START SWITCH DOES NOT ILLUMINATE (CONT). (b) Position main light switch auxiliary lever to PNL BRT (para 2-27c) and observe if FUEL gage illuminates. (c) Position main light switch auxiliary lever to OFF (para 2-27c). (d) Position main light switch main selector lever to OFF (para 2-27c). If FUEL gage illuminates, notify Unit Maintenance. If FUEL gage does not illuminate, perform Electrical System Troubleshooting e17A. FUEL Gage Does Not Illuminate. e16b. HAZARD LIGHTS SWITCH DOES NOT ILLUMINATE. Check to see if amber warning light switch illuminates. (a) Position main light switch main selector lever to SER DRIVE (para 2-27c). (b) Position main light switch auxiliary lever to PNL BRT (para 2-27c) and observe if amber warning light switch illuminates. (c) Position main light switch auxiliary lever to OFF (para 2-27c). (d) Position main light switch main selector to OFF (para 2-27c). If amber warning light switch illuminates, notify Unit Maintenance. If amber warning light switch does not illuminate, perform Electrical System Troubleshooting e16C. Amber Warning Light Switch Does Not Illuminate. e16c. AMBER WARNING LIGHT SWITCH DOES NOT ILLUMINATE. Check to see if master power switch illuminates. (a) Position main light switch main selector lever to SER DRIVE (para 2-27c). (b) Position main light switch auxiliary lever to PNL BRT (para 2-27c) and observe if master power switch illuminates. (c) Position main light switch auxiliary lever to OFF (para 2-27c). (d) Position main light switch main selector lever to OFF (para 2-27c). If master power switch illuminates, notify Unit Maintenance. If master power switch does not illuminate, perform Electrical System Troubleshooting e16D. Master Power Switch Does Not Illuminate. e16d. MASTER POWER SWITCH DOES NOT ILLUMINATE. Check to see if OIL PRESS gage illuminates. (a) Position main light switch main selector lever to SER DRIVE (para 2-27c). Change 1 3-39