TM-9-2320-366-10-2 MTV Operator Manual M1083 Series - Volume 2 Download
Page 350 of 930
TM 9-2320-366-10-2 2-55. OPERATION IN EXTREME DUST (CONT) b. Allow as much distance as possible between vehicles and operate at low speeds. c. Check and drain fuel/water separator (2) at stops (para 2-18, item 32). d. Park vehicle so that front of vehicle does not face into wind, when possible. e. Cover air intake, radiator, and cab with tarp during extended shutdown. CAUTION Keep glass surfaces covered with tarp as much as possible in blowing dust conditions. Failure to comply may result in scratched glass surfaces. f. Cover glass surfaces when not needed for operation. Take extra care when cleaning glass to prevent scratching surfaces. CAUTION Do not direct high-pressure water stream at glass surfaces, seals, air intake, exhaust outlet, or any other component of vehicle that could be easily damaged by high-pressure water stream. Failure to comply may result in damage to equipment. g. Clean dust from wheels, axles, universal joints, steering mechanism, and radiator as soon as possible. 2-724