TM-9-2320-366-10-2 MTV Operator Manual M1083 Series - Volume 2 Download
Page 218 of 930
TM 9-2320-366-10-2 2-48. M939/M939A1 AND M809 SERIES TOWING CONNECTION/DISCONNECTION (CONT) NOTE Left and right side lifting extensions are removed the same way. Right side shown. (24) Remove two lynch pins (27), pins (28), and lifting extensions (24) from M939/M939A1/M809 tow eyes (29). (25) Place STINGER lever (30) to IN position to retract stinger (31) until stinger cam lock (25) is aligned with first hole (32) in stinger. WARNING Stinger cam lock must be locked in first rectangular hole on stinger before underlift assembly is folded into its stowed position. Crossbar could shift suddenly. Failure to comply may result in injury to personnel. (26) Lock stinger cam lock (25). 2-604