TM-9-2320-366-10-1 MTV Operator Manual M1083 Series - Volume 1 Download
Page 363 of 802
TM 9-2320-366-10-1 CAUTION Do not engage starter pushbutton for more than 30 seconds. If engine fail s to start within this period, release starter pushbutton and wait two minut es before attempting to start engine. Failure to comply may result in dam age to equipment. (6) Press and hold starter pushbutton (7). (7) Release starter pushbutton (7) when engine starts. CAUTION • STOP indicator illuminates (red) to warn Operator when a potential engine failure (e.g., low oil pressure, low coolant, coolant over-heating, etc.) has occurred. Shut down engine immediately (para 2-27f) and perform Engine Troubleshooting (para 3-3). Failure to comply may result in damage to equipment. • If OIL PRESS gage does not show engine oil pressure of 15-80 psi (103-552 kPa) within 10-15 seconds after starting engine, shut down engine immediately (para 2-27f) and perform Engine Troubleshooting (para 3-3). Failure to comply may result in damage to equipment. (8) Check that WATER TEMP gage (8) reads between 100° F to 230° F (38°C to 110° C). If WATER TEMP gage reads in red zone and high engine temperature indicator (4) is illuminated, shut down engine (para 2-27f) and perform Engine Troubleshooting (para 3-3). Change 1 2-221