TM-9-2320-366-10-1 MTV Operator Manual M1083 Series - Volume 1 Download

Page 292 of 802

TM 9-2320-366-10-1 Table 2-5. Preventive Maintenance Checks and Services (M1089) Location Item No. Interval Item to Check/ Service Crewmember Procedure Not Fully Mission Capable If: CAUTION Shutoff valve and return valve must be opened before Material Handling Crane (MHC), underlift assembly, stifflegs, or 30K winches are operated. Failure to comply may result in damage to equipment. 1 Before Shutoff and Return Valve a. Check that shutoff and return valves are open. Open valves as required. b. Check that hydraulic hoses are not damaged or leaking. b. Class III leak is evident. 2-154