TM 9-2320-366-10-1 Change 2 2-129 Table 2-2. Preventive Maintenance Checks and Services (M1083, M1084, M1085, M1086, and M1093) Location Item No. Interval Item to Check/ Service Crewmember Procedure Not Fully Mission Capable If: 10 Monthly LMHC (if equipped) (Cont) d. Check security of electrical connectors on overload shutdown box. e. Inspect electrical cables for cracking, fraying, and chaffing. e. Wiring is frayed, cracked, or excessively worn.