TM 9-2320-365-34-2  (131) Position coolant fill hose (176) on hose fitting (177) with  clamp (178).  (131.1) Tighten clamp (178) to 34-44 lb-in. (4-5 N·m).  CAUTION  Ensure hoses and connection points are  tagged correctly prior to disconnecting.  Failure to comply may result in air system not  being able to pressurize.  (132) Connect two unloader valve hoses (179) to adapters  (34).  (133) Connect air compressor pressure hose (180) to 90-  degree fitting (35).  (134) Install air compressor intake hose (181) on 45-degree  fitting (182) with clamp (183).  (135) Install coolant bypass hose (184) on coolant tube (31)  with clamp (185).  Change 1 3-53