TM 9-2320-365-34-2 18-58 Change 2 All data on pages 18-59 thru 18-124, including page 18-59 through 18-124 deleted. 18-5. ENHANCED RESILIENT MOUNT INITIAL INSTALLATION (CONT) (7) Apply sealing compound to threads of bolt (2). (8) Position spacer (8) and enhanced resilient mount (9) on bolt (2). (9) Tighten resilient mount (9) 1½turns after contact with plate (4). (10) Remove C-clamp from leaf spring (1). e. Follow-On Maintenance. (1) Install gravel deflector (TM 9-2320-365-10). (2) Install front leaf spring (TM 9-2320-365-34). (3) Lower cab (TM 9-2320-365-10). End of Task. WARNING Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel.