TM-9-2320-365-34-2 LMTV Direct Maintenance Manual M1078 Series - Volume 2 Download
Page 932 of 1414
TM 9-2320-365-34-2  18-3. 200 AMP ALTERNATOR REPAIR (CONT)  (35) Position terminal lugs (49 and 50), washer (51), and  lockwasher (52) on 12 vdc post (3) with screw (53).  (36) Tighten screw (53) to 80 lb-in. (9 N·m).  (37) Apply sealing compound to screw (53), lockwasher (52),  washer (51), and terminal lugs (49 and 50).  (38) Position terminal lugs (54 and 55), washer (56), and  lockwasher (57) on 24 vdc post (8) with screw (58).  (39) Tighten screw (58) to 80 lb-in. (9 N·m).  WARNING  Adhesives, solvents, and sealing  compounds can burn easily, can give off  harmful vapors, and are harmful to skin  and clothing. Keep away from open fire  and use in a well-ventilated area. If  adhesive, solvent, or sealing compound  gets on skin or clothing, wash  immediately with soap and water. Failure  to comply may result in injury to  personnel.  (40) Apply sealing compound to screw (58), lockwasher (57),  washer (56), and terminal lugs (55 and 54).  18-24 Change 1