Page 869 of 1414

TM 9-2320-365-34-2 d. Counterbalance Valve Installation. (1) Install two preformed packings (1) in hydraulic motor (2). (2) Install two preformed packings (3) on 90-degree fittings (4). (3) Install two 90-degree fittings (4) in counterbalance valve (5). (4) Install preformed packing (6) in counterbalance valve (5). (5) Install counterbalance valve (5) on hydraulic motor (2). (6) Position four screws (6) in counterbalance valve (5). (7) Position screw (7) in counterbalance valve (5). (8) Tighten four screws (6) to 25 lb-ft (34 N·m). (9) Tighten screw (7) to 8 lb-ft (11 N·m). (10) Connect two hydraulic hoses (8) to 90-degree fittings (4). Change 1 16-21