TM-9-2320-365-34-2 LMTV Direct Maintenance Manual M1078 Series - Volume 2 Download

Page 793 of 1414

TM 9-2320-365-34-2 (78) Route power distribution panel 24 vdc cable (75) and power distribution panel 12 vdc cable (76) inside dashboard (94). (79) Remove screw (112) from power distribution panel (107). (80) Position four terminal lugs (113), terminal lug TL42 (114), lockwasher (115), and screw (112) on power distribution panel (107). (81) Tighten screw (112) to 35-45 lb-in. (4-5 N·m). (82) Remove screw (116) from power distribution panel (107). (83) Position four terminal lugs (117), terminal lugs TL41 (118), lockwasher (119), and screw (116) on power distribution panel (107). (84) Tighten screw (116) to 35-45 lb-in. (4-5 N·m). 15-85