TM 9-2320-365-34-2 CAUTION Cap or plug hoses and disconnection points to prevent contamination of pneumatic system. Failure to comply may result in damage to equipment. NOTE • Tag hoses and connection points prior to disconnecting. • Remove plastic cable ties as required. (6) Disconnect hose (27) from 90-degree fitting (28). (7) Remove nut (29) and 90-degree fitting (28) from frame rail (4). CAUTION When removing bolts, continuous removal of collars is mandatory. Failure to comply will result in seizing of collar to bolt. (8) Remove three collars (30) and bolts (31) from bracket (32). Discard collars and bolts. (9) Remove three self-locking nuts (33), six washers (34), three screws (35), and bracket (36) from valve panel (37). Discard self-locking nuts. 13-19