TM 9-2320-365-34-2 b. Installation. (1) Install seal (1) in housing (2). (2) Install gasket (3) on channel plate (4). (3) Install strainer (5) on channel plate (4). NOTE Perform steps (4) and (5) on serial number 6510032369 and higher. (4) Position housing (2) on channel plate (4) with three bolts (6). (5) Tighten three bolts (6) to 108-120 lb-in. (12-14 N·m). NOTE Perform steps (6) and (7) on serial numbers prior to 6510032369. (6) Position housing (2) on channel plate (4) with four bolts (6). (7) Tighten four bolts (6) to 108-120 lb-in. (12-14 N·m). c. Follow-On Maintenance. Install control valve module (para 7-10). End of Task. 7-93