TM-9-2320-365-34-2 LMTV Direct Maintenance Manual M1078 Series - Volume 2 Download
Page 321 of 1414
TM 9-2320-365-34-2  Change 2 7-16.1/(7-16.2 Blank)  Table 7-2  Torque Converter End Play Shim Chart  DIMENSION C USE P/N  SHIM THICKNESS  0.4093-0.6597 mm  0.016-0.026 in.  29505688 0.000  NO STEP  0.6598-0.8377 mm  0.026-0.033 in.  29505681 0.178-0.288 mm  0.007-0.009 in.  0.8378-1.0157 mm  0.033-0.040 in.  29505682 0.356-0.406 mm  0.014-0.016 in.  1.0156-1.1937 mm  0.040-0.047 in.  29505683 0.534-0.584 mm  0.021-0.023 in.  1.1938-1.3707 mm  0.047-0.054 in.  29505684 0.711-0.761 mm  0.028-0.030 in.  1.3708-1.5487 mm  0.054-0.061 in.  29505685 0.889-0.939 mm  0.035-0.037 in.  1.5486-1.6823 mm  0.061-0.066 in.  29505686 1.067-1.117 mm  0.042-0.044 in.  (10) Remove profile gage bolt and profile gage from  torque converter module (1).  NOTE  Based on dimension "C", select proper shim from Table 7-2 Torque Converter End Play Shim Chart.