TM 9-2320-365-34-2 6-6. STARTING MOTOR REPAIR (P/N M0017703ME) (CONT) (43) Install boot (52) on link spool (53). CAUTION Use care not to damage link spool during installation. Failure to comply may result in damage to equipment. (44) Wrap three layers of abrasive cloth around plunger (54). (45) Position boot (52) and link spool (53) in plunger (54). (46) Hold plunger (54) in a fixed position. (47) Tighten link spool (53) to 27-33 lb-in. (3-4 N·m). NOTE Hold the shift housing end up for installation of solenoid. (48) Position starting motor solenoid (55) in shift housing (33). (49) Rotate starting motor solenoid (55) so mounting bracket is facing down. WARNING Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing. Keep away from open fire and use in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. Failure to comply may result in injury to personnel. (50) Apply sealing compound to threads of two screws (56). NOTE Steps (51) and (52) require the aid of an assistant. (51) Position two screws (56) in starting motor solenoid (55). (52) Tighten two screws (56) to 20-24 lb-ft (27-32 N·m). 6-36.14 Change 1