TM-9-2320-365-34-2 LMTV Direct Maintenance Manual M1078 Series - Volume 2 Download

Page 1134 of 1414

TM 9-2320-365-34-2 22-4. TRANSFER CASE HOUSING REPAIR (CONT) (27) Remove plug (49) from transfer case cover (3). (28) Remove preformed packing (50) from plug (49). Discard preformed packing. (29) Remove plug (51) and two orifice plugs (52) from transfer case cover (3). (30) Remove plug (53) and orifice plug (54) from transfer case housing (22). (31) Remove two plugs (55) from transfer case housing (22). (32) Remove two preformed packings (56) from plugs (55). Discard preformed packings. (33) Remove two dowels (57) from transfer case housing (22). b. Cleaning/Inspection. WARNING Dry Cleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and gloves; use only in well ventilated area; avoid contact with skin, eyes, and clothes, and do not breathe vapors. Keep away from heat or flame. Never smoke when using solvent; the flashpoint for Type I Dry Cleaning Solvent is 100°F (38°C) and for Type II is 130°F (50°C). Failure to comply may result in serious injury or death to personnel. If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical help. If dry cleaning solvent contacts skin or clothes, flush with cold water. If dry cleaning solvent contacts eyes, immediately flush eyes with water and get immediate medical attention. Failure to comply may result in injury to personnel. (1) Clean all metal parts with dry cleaning solvent. 22-14