TM-9-2320-365-34-1 LMTV Direct Maintenance Manual M1078 Series - Volume 1 Download

Page 929 of 1334

CAUTION TM 9-2320-365-34-1 Change 1 2-835 CONTINUITY TEST Use care when disconnecting transmission internal wiring harness connectors. Failure to comply may result in damage to equipment. (1) Remove valve body cover (para 8-2). (2) Disconnect transfer case wiring harness connector H from H solenoid. (3) Set multimeter to ohms. (4) Connect positive (+) probe of multimeter to transfer case connector pin A. (5) Connect negative (-) probe of multimeter to transfer case wiring harness connector socket A. (6) If continuity is not present, replace transfer case wiring harness (para 8-2). (7) Connect positive (+) probe of multimeter to transfer case connector pin A. (8) Connect negative (-) probe of multimeter to all other pins in transfer case connector and note reading on multimeter. (9) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (10) If continuity is present, transfer case wiring harness is shorted; replace transfer case wiring harness (para 8-2).