TM-9-2320-365-34-1 LMTV Direct Maintenance Manual M1078 Series - Volume 1 Download
Page 867 of 1334
TM 9-2320-365-34-1  Change 1 2-773  CONTINUITY TEST  CAUTION  Use care when disconnecting wiring harness  connectors. Failure to comply may result in  damage to equipment.  (1) Loosen screw in adapter cable 24-pin  connector.  (2) Disconnect adapter cable 24-pin connector  from internal wiring harness 24-pin  connector.  (3) Set multimeter to ohms.  (4) Connect positive (+) probe of multimeter  to adapter cable 31-pin connector pin K.  (5) Connect negative (-) probe of multimeter  to adapter cable 24-pin connector pin E1  and note reading on multimeter.  (6) If continuity is not present, replace  transmission adapter cable assembly  (para 6-8).  (7) Connect positive (+) probe of multimeter  to adapter cable 31-pin connector pin K.  (8) Connect negative (-) probe of multimeter  to all other pins in adapter cable 31-pin  connector and note reading on multimeter.  (9) Connect negative (-) probe of multimeter  to ground and note reading on multimeter.  (10) If continuity is present, transmission  adapter cable assembly is shorted; replace  transmission adapter cable assembly  (para 6-8).