TM-9-2320-365-34-1 LMTV Direct Maintenance Manual M1078 Series - Volume 1 Download
Page 721 of 1334
Change 1 2-627 TM 9-2320-365-34-1 (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to internal wiring harness 31-pin connector pin N. (3) Connect negative (-) probe of multimeter to internal wiring harness 31-pin connector pin P and note reading on multimeter. (4) If continuity is not present, replace transmission internal wiring harness (para 7-13). (5) Connect connector P67 to internal wiring harness 31-pin connector. CONTINUITY TEST