TM-9-2320-365-34-1 LMTV Direct Maintenance Manual M1078 Series - Volume 1 Download
Page 721 of 1334
Change 1 2-627  TM 9-2320-365-34-1  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter to  internal wiring harness 31-pin connector  pin N.  (3) Connect negative (-) probe of multimeter  to internal wiring harness 31-pin connector  pin P and note reading on multimeter.  (4) If continuity is not present, replace  transmission internal wiring harness  (para 7-13).  (5) Connect connector P67 to internal wiring  harness 31-pin connector.  CONTINUITY TEST