Change 1 2-549 TM 9-2320-365-34-1 (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector P119-A. (3) Connect negative (-) probe of multimeter to external wiring harness 24-pin connector pin H2 and note reading on multimeter. (4) If continuity is not present, replace transmission external wiring harness (para 6-7). (5) Connect positive (+) probe of multimeter to connector P119-A. (6) Connect negative (-) probe of multimeter to all other pins in connector P119 and note reading on multimeter. (7) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (8) If continuity is present, transmission external wiring harness is shorted; replace transmission external wiring harness (para 6-7). (9) Connect connector P119 to connector J119. (10) Position front grille on cab with washer and screw. CONTINUITY TEST (11) Position two washers and screws in front grille. (12) Tighten screw to 48-60 lb-in. (5-7 N·m). (13) Tighten two screws to 24 lb-in. (3 N·m).