TM-9-2320-365-34-1 LMTV Direct Maintenance Manual M1078 Series - Volume 1 Download
Page 577 of 1334
TM 9-2320-365-34-1 Change 1 2-487 CAUTION Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment. NOTE Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back and are capable of making good contact. RESISTANCE TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to N solenoid connector pin A. (3) Connect negative (-) probe of multimeter to N solenoid connector pin B and note reading on multimeter. (4) If resistance is less than 2.5 ohms or greater 5.0 ohms, replace N solenoid (para 7-7). (5) If resistance is between 2.5-5.0 ohms, replace WTEC II TEPSS (TM 9-2320-365- 20-3). (6) Connect internal wiring harness connector N to N solenoid connector. (7) Install cover on control valve module with four screws. (8) Install control valve module (para 7-10). (9) Connect batteries (TM 9-2320-365-20-3).