TM 9-2320-365-34-1  Change 1 2-469  CAUTION  Use care when testing electrical connectors.  Do not damage connector pins or sockets  with multimeter probes. Failure to comply  may result in damage to equipment.  NOTE  Inspect connector pins/sockets for damage,  corrosion, and serviceability. Check that  connector pins are not pushed back and  are capable of making good contact.  CONTINUITY TEST  (1) Loosen screw in adapter cable 24-pin  connector.  (2) Disconnect adapter cable 24-pin connector  from internal wiring harness 24-pin  connector.  (3) Set multimeter to ohms.  (4) Connect positive (+) probe of multimeter  to adapter cable 31-pin connector pin G.  (5) Connect negative (-) probe of multimeter to  adapter cable 24-pin connector pin H3 and  note reading on multimeter.  (6) If continuity is not present, replace  transmission adapter cable assembly  (para 6-8).  (7) Connect positive (+) probe of multimeter  to adapter cable 31-pin connector pin G.  (8) Connect negative (-) probe of multimeter to  all other pins in adapter cable 31-pin  connector and note reading on multimeter.  (9) Connect negative (-) probe of multimeter to  ground and note reading on multimeter.  (10) If continuity is present, transmission  adapter cable assembly is shorted; replace  transmission adapter cable assembly  (para 6-8).