TM-9-2320-365-34-1 LMTV Direct Maintenance Manual M1078 Series - Volume 1 Download
Page 497 of 1334
TM 9-2320-365-34-1  Change 1 2-409  CONTINUITY TEST  CAUTION  NOTE  Use care when testing electrical connectors.  Do not damage connector pins or sockets  with multimeter probes. Failure to comply  may result in damage to equipment.  Inspect connector pins/sockets for damage,  corrosion, and serviceability. Check that  connector pins are not pushed back and  are capable of making good contact.  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter  to internal wiring harness 24-pin connector  pin C2.  (3) Connect negative (-) probe of multimeter to  internal wiring harness connector G pin B  and note reading on multimeter.  (4) If continuity is not present, replace  transmission internal wiring harness  (para 7-13).  (5) Connect positive (+) probe of multimeter  to internal wiring harness 24-pin connector  pin C2.  (6) Connect negative (-) probe of multimeter to  all other pins in internal wiring harness  24-pin connector and note reading on  multimeter.  (7) Connect negative (-) probe of multimeter to  ground and note reading on multimeter.  (8) If continuity is present, transmission  internal wiring harness is shorted; replace  transmission internal wiring harness  (para 7-13).