TM-9-2320-365-34-1 LMTV Direct Maintenance Manual M1078 Series - Volume 1 Download
Page 411 of 1334
TM 9-2320-365-34-1  Change 1 2-323  CONTINUITY TEST  NOTE  CAUTION  Use care when testing electrical connectors.  Do not damage connector pins or sockets  with multimeter probes. Failure to comply  may result in damage to equipment.  Inspect connector pins/sockets for damage,  corrosion, and serviceability. Check that  connector pins are not pushed back and  are capable of making good contact.  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter  to connector P119-N.  (3) Connect negative (-) probe of multimeter to  external wiring harness 31-pin connector  pin H and note reading on multimeter.  (4) If continuity is not present, replace  transmission external wiring harness  (para 6-7).  (5) Connect positive (+) probe of multimeter  to connector P119-N.  (6) Connect negative (-) probe of multimeter to  all other pins in connector P119 and note  reading on multimeter.  (7) Connect negative (-) probe of multimeter to  ground and note reading on multimeter.  (8) If continuity is present, transmission  external wiring harness is shorted; replace  transmission external wiring harness  (para 6-7).  (9) Connect connector P119 to connector  J119.  (10) Position front grille on cab with washer  and screw.  (11) Position two washers and screws in front  grille.  (12) Tighten screw to 48-60 lb-in. (5-7 N·m).  (13) Tighten two screws to 24 lb-in. (3 N·m).