TM-9-2320-365-34-1 LMTV Direct Maintenance Manual M1078 Series - Volume 1 Download

Page 201 of 1334

CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector P119-g. (3) Connect negative (-) probe of multimeter to external wiring harness transfer case connector pin D and note reading on multimeter. (4) If continuity is not present, replace transmission external wiring harness (para 6-7). (5) Connect positive (+) probe of multimeter to connector P119-g. (6) Connect negative (-) probe of multimeter to all other pins in connector P119 and note reading on multimeter. (7) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (8) If continuity is present, transmission external wiring harness is shorted; replace transmission external wiring harness (para 6-7). (9) Connect connector P119 to connector J119. (10) Position front grille on cab with washer and screw. (11) Position two washers and screws in front grille. (12) Tighten screw to 48-60 lb-in. (5-7 Nm). (13) Tighten two screws to 24 lb-in. (3 Nm). TM 9-2320-365-34-1 Change 1 2-115