TM-9-2320-365-34-1 LMTV Direct Maintenance Manual M1078 Series - Volume 1 Download
Page 193 of 1334
Change 1 2-107 TM 9-2320-365-34-1 CONTINUITY TEST CAUTION (1) Remove control valve module (para 7-10). (2) Remove four screws and cover from control valve module. (3) Remove internal wiring harness connector TSS from turbine speed sensor connector. (4) Set multimeter to ohms. (5) Connect positive (+) probe of multimeter to internal wiring harness 24-pin connector pin E2. (6) Connect negative (-) probe of multimeter to internal wiring harness connector TSS pin A and note reading on multimeter. (7) If continuity is not present, replace transmission internal wiring harness (para 7-13). (8) Connect positive (+) probe of multimeter to internal wiring harness 24-pin connector pin E2. (9) Connect negative (-) probe of multimeter to all other pins in internal wiring harness 24-pin connector and note reading on multimeter. (10) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (11) If continuity is present, transmission internal wiring harness is shorted; replace transmission internal wiring harness (para 7-13). Use care when disconnecting wiring harness connectors. Failure to comply may result in damage to equipment.