TM-9-2320-365-34-1 LMTV Direct Maintenance Manual M1078 Series - Volume 1 Download
Page 1076 of 1334
TM 9-2320-365-34-1 TM 9-2320-365-34-1 TM 9-2320-365-34-1 TM 9-2320-365-34-1 TM 9-2320-365-34-1 REASON FOR QUESTION TEST OPTIONS NO YES Flow and Pressure Test KNOWN INFO POSSIBLE PROBLEMS CAUTION Read WARNING and CAUTION on following page. WARNING START 1. Tools and Special Tools Tool Kit, Genl Mech (Item 68, Appendix B) Tester, Hydraulic (Item 63, Appendix B) Pan, Drain (Item 36, Appendix B) Goggles, Industrial (Item 25, Appendix B) STE/ICE-R (Item 60, Appendix B) Personnel Required (2) References TM 9-4910-571-12&P Hydraulic oil level OK. Hydraulic hoses, tubes, and fittings OK. 11K Self-recovery winch electric circuit OK. Hydraulic oil tank, filters, and strainers OK. 11K Self-recovery winch control valve assembly OK. Is there 15-18 GPM (57-70 lpm) at 2000-2100 psi (13790-14480 kPa) measured at output of hydraulic rotary pump? If hydraulic rotary pump flow and pressure is not correct, hydraulic rotary pump is faulty. g1. 11K SELF-RECOVERY WINCH DOES NOT WORK Faulty counterbalance valve. Faulty cartridge valve. Faulty 11K self-recovery winch hydraulic motor. Faulty 11K self-recovery winch. Faulty hydraulic rotary pump. Replace hydraulic rotary pump (para 16-5). INITIAL SETUP Equipment Conditions Engine shut down (TM 9-2320-365-10). Materials/Parts Rag, Wiping (Item 59, Appendix C) Hose (2) (Item 41, Appendix C) Fitting (2) (Item 32, Appendix C) Fitting (Item 33, Appendix C) Reducer, Tube (Item 60, Appendix C) Adapter, Swivel (Item 3, Appendix C) Adapter, Pipe (Item 2, Appendix C) Adapter, Pipe (Item 1, Appendix C) 2-976 2-976 2-976 2-976 2-976