Change 1 2-905  TM 9-2320-365-34-1  CONTINUITY TEST  CAUTION  Use care when disconnecting wiring harness  connectors. Failure to comply may result in  damage to equipment.  (1) Remove control valve module (para 7-10).  (2) Remove four screws and cover from  control valve module.  (3) Disconnect internal wiring harness  connector F from F solenoid.  (4) Set multimeter to ohms.  (5) Connect positive (+) probe of multimeter  to internal wiring harness 24-pin connector  pin D3.  (6) Connect negative (-) probe of multimeter  to internal wiring harness connector F  pin A and note reading on multimeter.  (7) If continuity is not present, replace  transmission internal wiring harness  (para 7-13).  (8) Connect positive (+) probe of multimeter  to internal wiring harness 24-pin connector  pin D3.  (9) Connect negative (-) probe of multimeter  to all other pins in internal wiring harness  24-pin connector and note reading on  multimeter.  (10) Connect negative (-) probe of multimeter  to ground and note reading on multimeter.  (11) If continuity is present, transmission  internal wiring harness is shorted; replace  transmission internal wiring harness  (para 7-13).