TM 9-2320-365-20-5 20-45. M1079 HEATER THERMOSTAT CABLE REPLACEMENT This task covers: a. Removal b. Installation c. Follow-On Maintenance INITIAL SETUP Equipment Conditions Engine shut down (TM 9-2320-365-10). AC power disconnected (TM 9-2320-365-10). LH and RH doors opened (115 degrees) (TM 9-2320- 365-10). Tools and Special Tools Tool Kit, Genl Mech (Item 44, Appendix C) Materials/Parts Dispenser, Pressure Sensitive Adhesive Tape (Item 21, Appendix D) a. Removal. NOTE Tag connectors and connection points prior to disconnecting. (1) Disconnect connector J245 (1) from thermostat connector (2). (2) Disconnect connector P245A (3) from heater control unit (4). b. Installation (1) Connect connector P245A (3) to heater control unit (4). (2) Connect connector J245 (1) to thermostat connector (2). c. Follow-On Maintenance. (1) Connect AC power (TM 9-2320-365-10). (2) Check thermostat for proper operation (TM 9-2320-365- 10). (3) Close LH and RH doors (TM 9-2320-365-10). End of Task. 20-236